Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Prosthet Dent ; 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36841707

RESUMO

STATEMENT OF PROBLEM: Rehabilitation with wide-diameter reduced-length implants has become popular for patients with minimal vertical bone. However, a consensus on the benefits of this approach is lacking. PURPOSE: The purpose of this systematic review with meta-analysis was to evaluate the influence of wide compared with regular diameter on the clinical performance of short (<10 mm) and extrashort (≤6 mm) dental implants used for rehabilitations with single crowns, fixed partial dentures, or both, in the posterior region. MATERIAL AND METHODS: A search in 6 databases was conducted to select randomized controlled trials (RCTs) and nonrandomized controlled trials (N-RCTs). Five meta-analyses were performed, where the risk ratio (RR) was evaluated. The certainty of evidence was evaluated, and the risk of bias was determined from the Joanna Briggs Institute checklist. RESULTS: Fourteen articles were included, 272 wide- and 478 regular-diameter implants. One study presented a low, 3 an unclear, and 11 a high risk of bias. Meta-analyses showed no statistical difference: implant survival, short dental implants in N-RCTs (up to 1 year - RR 1.01 [0.98; 1.03], 1 to 5 years - RR 1.01 [0.94; 1.08], more than 5 years - RR 1.01 [0.97; 1.06]), extrashort dental implants in N-RCTs (RR 1.04 [0.90; 1.20]), RCTs (RR 1.05 [0.88; 1.25]); implant success in N-RCTs (RR 1.01 [0.97; 1.05]); prosthesis success in N-RCTs (RR 1.01 [0.97; 1.05]). CONCLUSIONS: Short and extrashort dental implants with a wide and regular diameter appear to be clinically appropriate options for implant-supported posterior restorations, with high survival, success, and prosthesis success rates.

2.
Artigo em Inglês | MEDLINE | ID: mdl-36704649

RESUMO

Background: Hepatic epithelioid hemangioendothelioma (HEHE) is a rare neoplastic disease of varied presentation and unspecific radiological signs in the early stages. The diagnostic delay can lead to metastatic disease, thus increasing the tumor burden and reducing the treatment options. HEHE is usually deemed a slow-growing tumor, but its speed of growth is poorly reported and still unknown. Case Description: In this case report, we documented a HEHE diagnosed in a young woman who had complaints of abdominal pain, weight loss and bloating for a long time. The typical findings observed in histological studies were not promptly recognized in the histological analyzes, even after two laparoscopic-guided liver biopsies, delaying the diagnosis until extrahepatic tumor spreading. Findings observed in computed tomography, magnetic resonance imaging and histological studies are presented. The coalescence of nodules and the rising of giant masses, occupying large parts of the liver in a specific time span, were registered and quantified. As opposed to prior reports, the results show that hepatic HEHE can grow rapidly, reinforcing the need of early diagnosis, thus avoiding the complications presented herein. Conclusions: The findings observed via radiological and histological imaging that could have avoided the diagnosis delay are depicted and discussed, showing that HEHE can rise faster than previously documented.

3.
Braz. j. oral sci ; 22: e238152, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1437694

RESUMO

Aim: This study evaluated the influence of a wide diameter on extra-short dental implant stress distribution as a retainer for single implant-supported crowns in the atrophic mandible posterior region under axial and oblique load. Methods: Four 3D digital casts of an atrophic mandible, with a single implant-retained crown with a 3:1 crown-to-implant ratio, were created for finite element analysis. The implant diameter used was either 4 mm (regular) or 6 mm (wide), both with 5 mm length. A 200 N axial or 30º oblique load was applied to the mandibular right first molar occlusal surface. The equivalent von Mises stress was recorded for the abutment and implant, minimum principal stress, and maximum shear stress for cortical and cancellous bone. Results: Oblique load increased the stress in all components when compared to axial load. Wide diameter implants showed a decrease of von Mises stress around 40% in both load directions at the implant, and an increase of at least 3.6% at the abutment. Wide diameter implants exhibited better results for cancellous bone in both angulations. However, in the cortical bone, the minimum principal stress was at least 66% greater for wide than regular diameter implants, and the maximum shear stress was more than 100% greater. Conclusion: Extra-short dental implants with wide diameter result in better biomechanical behavior for the implant, but the implications of a potential risk of overloading the cortical bone and bone loss over time, mainly under oblique load, should be investigated


Assuntos
Implantes Dentários , Arcada Parcialmente Edêntula , Prótese Dentária Fixada por Implante , Análise de Elementos Finitos
4.
J Prosthet Dent ; 2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35931572

RESUMO

STATEMENT OF PROBLEM: Evidence regarding the retention system for a mandibular overdenture is important for treatment planning. However, the clinical performance of stud and ball attachments for mandibular overdenture retainers is unclear. PURPOSE: The purpose of this systematic review and meta-analysis was to compare the clinical performance and self-reported patient outcomes of ball and stud attachments as mandibular overdenture retainers. MATERIAL AND METHODS: Randomized (RCTs) and nonrandomized (N-RCTs) controlled clinical trials were selected based on the eligibility criteria. The risk of bias was assessed by using the Cochrane Collaboration Tools, and the certainty of the evidence (COE) by using the grades of recommendation, assessment, development, and evaluation (GRADE) workshop approach. Meta-analyses according to the follow-up period were performed for implant survival, prosthetic maintenance and complications, bleeding on probing (BoP), marginal bone loss (MBL), satisfaction, and oral health-related quality of life (OHRQoL). RESULTS: Thirteen RCTs and 4 N-RCTs were included. Twelve studies presented a high risk of bias. The stud demonstrated a lower risk ratio (RR) (P<.001) for maintenance and complications concerning the need for matrix activation (RR 7.12 [2.65, 19.15]) (very low COE) and new overdentures (RR 2.47 [1.02, 5.96]) (moderate COE), ranging from 1 to 5 years of follow-up. Mean difference (MD) for MBL after 1 (MD 0.40 [0.28, 0.52]; P<.001) and 5 years (MD 0.18 [0.16, 0.20]; P<.001) was higher for ball attachments than that for stud (very low COE) attachments. Stud attachments also improved satisfaction (P<.001) when compared with ball attachments (very low COE). Implant survival rate (high COE), BoP (very low COE), and OHRQoL (low COE) were similar for the attachments. CONCLUSIONS: Stud and ball attachments are clinically appropriate options as mandibular overdenture retainers and are capable of restoring OHRQoL. Nevertheless, the stud showed greater improvement in satisfaction and less prosthetic aftercare and MBL.

5.
J Prosthet Dent ; 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35864024

RESUMO

STATEMENT OF PROBLEM: Implant-supported single crowns are more prone to screw loosening than splinted prostheses. Therefore, the locking taper system, which has a screwless abutment, may perform better when associated with this type of rehabilitation. However, systematic reviews on this system are lacking. PURPOSE: The purpose of this systematic review was to evaluate the clinical performance and complications of single crowns retained by the locking taper system. MATERIAL AND METHODS: This systematic review was registered at the International Prospective Register of Systematic Reviews (PROSPERO) under CRD42020189921. An electronic search was made in 5 databases and 3 other sources up to February 2021 to select prospective clinical studies evaluating the performance of single crowns retained by the locking taper system by using the outcomes implant survival, success rate, complications, marginal bone loss (MBL), and prosthesis success rate. Four meta-analyses grouped according to the follow-up intervals were performed. The risk of bias of the selected studies was evaluated by using the RoB 2 checklist for randomized controlled trials (RCTs) and Downs and Black for uncontrolled studies. RESULTS: Twelve studies were included: 9 prospective cohort studies and 3 RCTs. A survival rate of 99% (98% to 99%) and a success rate of 97% (92% to 99%) after 5 years were found. Of the total, 2.6% biological and 2.9% prosthetic complications were described. The prosthesis success rate was 97% (96% to 98%) after 5 years. An average of -0.73 mm (-0.93 to -0.52) was found for the MBL after 5 years. The risk-of-bias assessment showed 2 RCTs with high risk and 1 RCT with low risk of bias. Among uncontrolled studies, 2 were classified as poor and 7 as fair. CONCLUSIONS: Single crowns retained by locking taper implants can be safely indicated based on the high survival and success rates achieved in the long term, the maintenance of bone level stability over time, and the low incidence of complications.

6.
Braz. j. oral sci ; 20: e214873, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1254742

RESUMO

Aim: To compare the marginal fit of lithium disilicate CAD/CAM crowns and heat-pressed crowns fabricated using milled wax patterns, and evaluate its effect on stress distribution in implantsupported rehabilitation. Methods: A CAD model of a mandibular first molar was designed, and 16 lithium disilicate crowns (8/group) were obtained. The crown-prosthetic abutment set was evaluated in a scanning electron microscopy. The mean misfit for each group was recorded and evaluated using Student's t-test. For in silico analysis, a virtual cement thickness was designed for the two misfit values found previously, and the CAD model was assembled on an implant-abutment set. A load of 100 N was applied at 30° on the central fossa, and the equivalent stress was calculated for the crown, titanium components, bone, and resin cement layer. Results: The CAD/CAM group presented a significantly (p=0.0068) higher misfit (64.99±18.73 µm) than the heat-pressed group (37.64±15.66 µm). In silico results showed that the heat-pressed group presented a decrease in stress concentration of 61% in the crown and 21% in the cement. In addition, a decrease of 14.5% and an increase of 7.8% in the stress for the prosthetic abutment and implant, respectively, was recorded. For the cortical and cancellous bone, a slight increase in stress occurred with an increase in the cement layer thickness of 5.9% and 5.7%, respectively. Conclusion: The milling of wax patterns for subsequent inclusion and obtaining heat-pressed crowns is an option to obtain restorations with an excellent marginal fit and better stress distribution throughout the implant-abutment set


Assuntos
Microscopia Eletrônica de Varredura , Desenho Assistido por Computador , Adaptação Marginal Dentária , Prótese Dentária Fixada por Implante , Análise de Elementos Finitos , Materiais Dentários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...